C&I BESS · RFQ Guide
Get a Quote →The C&I BESS RFQ Checklist: 12 Technical Questions That Reveal Whether the Supplier Understands Your Project
Most RFQs ask three things: capacity, PCS power, and warranty. Suppliers fill the blanks with different assumptions, and the quotes become incomparable. Here are the 12 technical questions that expose the engineering depth behind a BESS quote — before you sign.
Key Takeaways
- An RFQ that lists only capacity, PCS power, and warranty lets suppliers fill the gaps with different assumptions, making their quotes incomparable.
- The 12 technical questions cover five dimensions: capacity and energy; BMS and communication; safety and fire protection; expansion and warranty; operations and data.
- These questions test alignment with your project requirements and applicable industry standards, rather than asking suppliers to endorse their own specifications.
- An engineering-grade RFQ requires assumptions, test methods, and a document list alongside the price.
- At the RFQ stage, JKESS can provide protocol mapping documents, auxiliary power curves, fire-test configuration descriptions, and expansion boundary information to support a comparable evaluation.
Why Three-Line RFQs Produce Incomparable Quotes
Early in commercial and industrial (C&I) battery energy storage system (BESS) procurement, a buyer’s request for quotation (RFQ) often contains just three lines: required capacity in kWh, power conversion system (PCS) rating in kW, and warranty duration. These three lines do not define a system, but they leave plenty of room for suppliers to fill in the missing assumptions differently.
One supplier may calculate usable energy at 90% depth of discharge (DOD), while another uses 80%. One may deduct auxiliary consumption, while another excludes it. One may design cooling around a 25°C ambient temperature, while another accounts for derating at 45°C. All three quotes can read “500 kWh + 100 kW + 10-year warranty,” yet describe materially different delivered systems.
The buyer is therefore comparing different products under different assumptions. To make quotes comparable, the RFQ must move from “what do we need?” to “under what conditions, measured by which method, and supported by which documents?” The NREL Annual Technology Baseline for battery storage provides useful context for distinguishing power, energy, storage duration, and performance assumptions.
The 12 Questions, Grouped by Evaluation Dimension
Swipe horizontally to read the full checklist.
| # | Dimension | Question to Put in the RFQ |
|---|---|---|
| 1 | Capacity & Energy | What power-to-energy ratio is assumed? What is the engineering rationale for pairing the PCS rated power with the battery nominal capacity? |
| 2 | Capacity & Energy | Does “usable energy” account for auxiliary consumption and the SOC operating window? What is the net usable energy after these deductions? |
| 3 | Capacity & Energy | At what depth of discharge (DOD) and temperature is cycle life defined? Are separate cycle counts provided for 90% DOD and 50% DOD? |
| 4 | BMS & Communication | How is state-of-charge (SoC) accuracy calibrated? What triggers resting calibration and online correction? |
| 5 | BMS & Communication | Will you provide a byte-level communication protocol mapping document, including CAN message IDs and RS485 register addresses? |
| 6 | BMS & Communication | When multiple battery clusters operate in parallel, how are circulating current and inter-cluster SOC deviation monitored and managed? |
| 7 | Safety & Fire Protection | Was fire testing performed at unit level or in an installation-level configuration? Does the tested configuration match my installation scenario? |
| 8 | Safety & Fire Protection | What is the protection-action logic for insulation monitoring, pre-charge control, and the high-voltage interlock? |
| 9 | Expansion & Warranty | Will future expansion require replacing the master box? What are the maximum supported slave count and the available PCS power margin? |
| 10 | Expansion & Warranty | How is warranty capacity retention measured? What test conditions, test equipment, and report format are used? |
| 11 | Operations & Data | Will you provide an auxiliary power consumption curve? What are the values under high-temperature and high-cycling operating conditions? |
| 12 | Operations & Data | Who owns the operational data? Can it be exported in standard formats, and does the cloud platform create supplier lock-in? |
Generic RFQ vs Engineering-Grade RFQ: What Changes in the Quote
Swipe horizontally to compare both RFQ approaches.
| Dimension | Generic RFQ (3 Lines) |
Engineering-Grade RFQ (12 Questions) |
|---|---|---|
| Capacity | “500 kWh” | Net usable energy after auxiliary load and SOC window |
| PCS Power | “100 kW” | Power-to-energy ratio and continuous/peak rating |
| Cycle Life | “6000 cycles” | Cycle count at specified DOD and temperature |
| SoC Accuracy | Not asked | Calibration method and accuracy target |
| Protocol | “Supports CAN” | Byte-level mapping document required |
| Parallel Operation | Not asked | Circulating current and SOC deviation management |
| Fire Safety | “Has fire suppression” | Test configuration vs installation scenario |
| Expansion | Not asked | Master box replacement and slave count limit |
| Warranty | “10 years” | Capacity retention test method and report format |
| Auxiliary Power | Not asked | Auxiliary power curve at high temperature and high cycling |
| Data Ownership | Not asked | Export format and cloud lock-in risk |
| Quote Comparability | Low — different assumptions | High — same assumptions, same metrics |
What These Questions Actually Verify
-
Capacity & Energy: Has your load profile been translated into the right system configuration?
Questions 1–3 require the supplier to explain capacity and cycling assumptions. Use your own 15-minute load data to check whether these assumptions match the project’s actual operating conditions.
-
BMS & Communication: Are your system integration boundaries covered?
Questions 4–6 require an explanation of SoC calibration, protocol mapping, and parallel cluster management. These answers help you assess whether the supplier understands the complexity of multi-cluster operation and third-party PCS integration.
-
Safety & Fire Protection: Does the test coverage include your installation scenario?
Questions 7–8 require the supplier to define fire-test configuration limits and protection-action logic. Compare the evidence with your installation space, equipment spacing, and fire-approval requirements to determine whether it applies to your site.
-
Expansion & Warranty: Is your long-term investment protected?
Questions 9–10 require the supplier to define expansion boundaries and warranty measurement methods. Use these answers to plan phased investment and confirm that capacity-retention commitments can be verified against agreed criteria.
-
Operations & Data: Can you control your operating costs?
Questions 11–12 require the supplier to explain auxiliary consumption and data access. Use this information to assess 10-year operating costs and the risk of being locked into a proprietary data platform.
What JKESS Provides During the RFQ Stage
Swipe horizontally to view products, formats, and RFQ coverage.
| Product / Document | Model / Format | What It Answers in the RFQ |
|---|---|---|
| 300A HV Master Box | HV-BC350 | Power-to-energy configuration, expansion boundaries, and communication interface definitions. |
| 200A HV Master Box | HV-BC250 | Master configuration and parallel management for medium-power battery clusters. |
| 100A HV Master Box | HV-BC150-100A | Capacity and cycling assumptions for small and medium-capacity projects. |
| 6U Slave Battery Box | HV Slave 6U Kits | Slave count, expansion limits, and cell consistency management. |
| 4U Slave Battery Box | HV Slave 4U Kits | Expansion and thermal-management boundaries for compact racks. |
| Communication & Warranty Documents | Protocol mapping documents, auxiliary power curves, and warranty measurement methods | Document delivery for questions 4–6 and 10–12; request the project-specific documentation package. |
Further Reading
-
NREL — Annual Technology Baseline: Utility-Scale Battery Storage
Cost and performance benchmarks with explicit storage-duration and operating assumptions. Use the utility-scale baseline as context, rather than as a direct quotation for a C&I project.
-
LBNL — Behind the Meter Solar+Storage: Market Data and Trends
Berkeley Lab research on behind-the-meter solar-plus-storage sizing, pricing, and customer financial and resilience value.
-
IEC 62619:2022 — Safety Requirements for Industrial Batteries
Safety requirements and tests for industrial lithium cells and batteries, including stationary applications. This is battery-safety context; it does not, by itself, establish that a particular site’s installation-level fire-test requirements are satisfied.
Frequently Asked Questions
Why is a three-line RFQ not enough for a C&I BESS project?
A three-line RFQ specifies capacity, PCS power, and warranty period, but leaves the underlying assumptions undefined. Different suppliers may use different DOD, temperature, auxiliary power, and SOC window assumptions, making the quotes incomparable. An engineering-grade RFQ specifies the assumptions and asks the supplier to state theirs.
What is the difference between nominal capacity and net usable energy?
Nominal capacity is the battery’s rated energy under specified reference conditions. Net usable energy is the energy delivered at an agreed measurement boundary, such as the AC point of connection, within the SOC operating window and after applicable discharge losses and auxiliary consumption. A 500 kWh nominal system may deliver significantly less usable energy. Specify round-trip efficiency separately as energy output divided by energy input; do not deduct the same losses twice.
Why does cycle life need to be specified at a given DOD and temperature?
Cycle life is not a single number. A battery cycled at 90% DOD will generally have fewer cycles than one cycled at 50% DOD. Temperature also affects degradation. Without specifying DOD and temperature, “6000 cycles” cannot be compared across suppliers.
What should a protocol mapping document include?
It should include the physical layer settings (baud rate, termination), the data link layer definitions (message IDs or register addresses, frame format, byte order), and the application layer definitions (data fields, units, scaling factors, alarm priorities, and protection actions).
How should a supplier demonstrate parallel cluster management?
The supplier should explain how per-cluster current is monitored, how SOC deviation between clusters is managed, and how circulating current is limited. This may include independent breakers and fuses per cluster, per-cluster current sensors, and cluster-level SOC balancing logic. Breakers and fuses provide protection; the supplier should separately identify the control strategy used to limit circulating current.
What does “fire test configuration” mean in the RFQ?
Fire tests, including large-scale fire testing, are performed under specific configurations — cell type, module spacing, installation height, and suppression method. If the buyer’s installation differs from the test configuration, the test data may not directly apply. The RFQ should ask the supplier to state the test configuration and its limits.
How should capacity retention be measured for warranty purposes?
The RFQ should specify the test conditions (temperature, C-rate, DOD), the test equipment, and the report format. Without a defined measurement method, the warranty’s capacity retention figure cannot be reliably verified against the agreed contractual criteria.
Why does auxiliary power consumption matter in the RFQ?
Auxiliary power — from cooling, BMS, and communication systems — reduces the net energy available for revenue-generating discharge. In high-temperature or high-cycling scenarios, auxiliary power can be a significant percentage of throughput. The RFQ should ask for the auxiliary power curve, not just a single value.
What does “data ownership” mean in a BESS RFQ?
Data ownership refers to who controls the operational data generated by the BESS and whether the buyer can export it in a standard format. If the data is locked in a supplier’s proprietary cloud, the buyer may face difficulties in warranty claims, performance analysis, or switching to another service provider.
Where can I find authoritative references for BESS cost and performance benchmarks?
NREL’s Annual Technology Baseline provides cost and performance data for utility-scale battery storage. LBNL publishes research on behind-the-meter battery storage value and costs. IEC 62619 defines safety requirements for industrial lithium cells and batteries. These references provide general benchmarks and safety context, but project-specific assumptions should always be verified with the supplier.
Want to Compare BESS Quotes on the Same Assumptions?
Share your RFQ draft with our engineering team. We’ll help you identify which assumptions are missing, which questions to add, and how to structure the quote comparison — before you send it to suppliers.
Request a Custom Quote →