All Categories
bmu h5 52 slave-0

HV Slave BMS

Home >  Product >  HV BMS >  HV Slave BMS

BMU-H5-52 (slave)

  • Overview
  • Related Products

英文版产品主图设计需求.png
JKESSby JKBMS Electronic Technology Co., Ltd.

BMU-H5-52 High-Voltage BMS Slave BMU

Reliable · Precise · Customizable — Engineered for 52S energy storage battery packs with ±4mV voltage accuracy and full CE / RoHS / FCC certification.

Availability:In Stock
Lead Time:15–30 Working Days

Why Choose JKESS

Data-driven results that deliver real economic and operational benefits for your energy storage projects.

±4mV

Ultra-High Voltage Accuracy

Cell voltage monitoring precision that ensures optimal battery balancing and extends pack lifespan.

🛡️99.7%

System Uptime

Proven reliability with CE, RoHS & FCC certifications — trusted by global ESS manufacturers.

🔧100%

Customizable Solutions

Full support for firmware tailoring, communication protocols, and harness customization for any project.

🏆15+

Patents & IP Rights

Independent intellectual property with multiple patent certificates — innovation you can trust.

CE Certified (2014/30/EU) RoHS Compliant (2011/65/EU) FCC Certified (Part 15)📜 Independent IP 15+ Patents

📦 Package Includes

  • 1x BMU-H5-52 Main Unit
  • 1x 52S Voltage Acquisition Harness
  • 1x NTC Temperature Sensor Harness
  • 1x Quick Start Guide

⚠️ Not Included (Sold Separately)

  • Battery Cells
  • Interconnect Wiring Harnesses
  • Rack / Cabinet Enclosures
  • Master BMS Controller (BCU)

Key Features of BMU-H5-52

📊

±4mV Voltage Accuracy

High-precision AFE chip for reliable cell voltage monitoring across full temperature range.

🌡️

57-Channel NTC Sensing

Comprehensive temperature monitoring with ±1°C accuracy for optimal thermal management.

🔗

CAN Communication

Robust 1x CAN interface for seamless data exchange with master BMS controllers.

⚖️

Passive Balancing

100mA effective balancing current with support for odd/even channel balancing.

🔌

Auto Address Assignment

Multi-slave cascade with automatic address encoding — plug and play.

🛡️

High Insulation & EMC

AC 3100V withstand voltage, EMC compliant with GB/T-18655, ISO11452, ISO7637.

🔄

Firmware OTA Upgrade

Supports CAN bus firmware upgrade for easy maintenance and feature updates.

🌍

Global Certifications

CE, RoHS, FCC certified — ready for worldwide deployment.

Customer Pain Points & Our Solutions

🔴 Common Pain Points
Inconsistent voltage readings leading to premature battery aging
Limited communication compatibility with existing BMS architectures
Long lead times and lack of customization support
Uncertainty about regulatory compliance (CE / RoHS / FCC)
Poor after-sales technical support and firmware updates
✅ How BMU-H5-52 Solves
±4mV accuracy with automotive-grade AFE — consistent, reliable data
Standard CAN interface plus customizable protocol support
15–30 day lead time with full firmware and harness customization
CE / RoHS / FCC certified — compliant out of the box
Full lifecycle support — pre-sales, installation, firmware, and 24/7 troubleshooting

Applications

🏭

Industrial & Commercial ESS

Peak shaving, load shifting, and backup power for factories, data centers, and commercial buildings.

🔋

Grid-Side Energy Storage

Frequency regulation, renewable integration, and grid stabilization for utility-scale projects.

🏗️

Battery Pack Integration

Seamless integration into 52S battery packs for OEMs and system integrators.

☀️

Solar + Storage

PV-coupled storage systems for residential, C&I, and community-scale renewable projects.

Technical Specifications

Parameter Specification
Product Type High-Voltage BMS Slave BMU (52S)
Voltage Acquisition Accuracy ±4mV (full temperature range)
Voltage Detection Range 0 ~ 5000mV per cell
Temperature Detection Accuracy ±1°C
NTC Temperature Channels Up to 57 channels
Balancing Type Passive balancing, 100mA effective current
Communication Interface 1x CAN
Operating Voltage DC 9V – 36V
Operating Current ≤ 35mA (12V) / ≤ 20mA (24V)
Operating Temperature −20°C ~ +65°C
Storage Temperature −40°C ~ +125°C
Insulation Withstand Voltage AC 4200V
Protection Class IP54 (non-waterproof)
EMC Compliance GB/T-18655; ISO11452; ISO7637; ISO10650; ISO16750
Standard Compliance GB/T 34131-2023
Dimensions 272 × 111 × 25 mm
Certifications CE · RoHS · FCC (with independent IP and patents)

Installation Notes

📋 Pre-Installation Checklist

  • Verify battery pack voltage (≤ 1000V system)
  • Confirm CAN communication wiring
  • Check NTC sensor placement
  • Ensure proper grounding

🔧 Key Installation Steps

  • Mount BMU securely in the battery pack
  • Connect voltage acquisition harness
  • Install NTC temperature sensors
  • Connect CAN bus to master controller

⚠️ Safety Precautions

  • Disconnect power before installation
  • Use ESD protection equipment
  • Follow local electrical safety codes
  • Refer to full installation manual

Selection Guide

Choose the right BMU configuration for your project. Follow this decision flow or contact our team for personalized assistance.

1 Define battery pack voltage / cell count
2 Select BMU model (52S / 48S / 64S)
3 Choose communication protocol
4 Confirm harness & sensor requirements
5Contact JKESS for final configuration

Procurement & Ordering Guide

📄 Required Documents

  • Project specification sheet
  • Battery pack configuration details
  • Communication protocol requirements
  • Quantity and delivery schedule

⚙️ Customization Options

  • Firmware tailoring for specific protocols
  • Custom harness length and connectors
  • Special temperature sensor configurations
  • Labeling and packaging preferences

🚚 Delivery & Shipping

  • Sample orders: 15–20 working days
  • Bulk orders: 25–30 working days
  • Global shipping via DHL / FedEx / sea freight
  • Tracking and customs support provided

Frequently Asked Questions

What is included in the BMU-H5-52 package?
The package includes 1x BMU-H5-52 main unit, 1x 52S voltage acquisition harness, 4x NTC temperature sensor harness, and 1x quick start guide. Battery cells, interconnect harnesses, and cabinets are sold separately.
What is the voltage acquisition accuracy of BMU-H5-52?
The BMU-H5-52 achieves ±4mV voltage acquisition accuracy across the full temperature range, ensuring reliable cell monitoring for high-voltage energy storage systems.
Is the BMU-H5-52 compatible with 1000V systems?
Yes, the BMU-H5-52 is designed for high-voltage applications and supports up to 1000V system architectures with 52S configuration.
What certifications does JKESS BMU-H5-52 hold?
The BMU-H5-52 is fully certified with CE, RoHS, and FCC. JKESS products also hold independent intellectual property rights and multiple patent certificates — ensuring quality and compliance for global markets.
What communication interfaces does the BMU-H5-52 support?
The BMU-H5-52 supports 1x CAN communication interface for reliable data exchange with the master BMS controller. Custom protocol support is available upon request.
Can the BMU-H5-52 be customized for specific projects?
Yes, JKESS offers full customization support including firmware tailoring, communication protocol adaptation, harness customization, and special sensor configurations to meet specific project requirements.
What is the operating temperature range of the BMU-H5-52?
The BMU-H5-52 operates reliably from −20°C to +65°C, with storage capability from −40°C to +125°C, suitable for diverse installation environments.
Does the BMU-H5-52 support passive balancing?
Yes, the BMU-H5-52 features passive balancing with an effective balancing current of 100mA, supporting both odd and even channel balancing for optimal cell equalization.
What is the typical lead time for BMU-H5-52 orders?
Standard lead time is 15–20 working days for sample orders and 25–30 working days for bulk orders, depending on quantity and customization requirements.
Does JKESS provide technical support after purchase?
Yes, JKESS offers full lifecycle technical support including pre-sales consultation, installation guidance, firmware updates, and after-sales troubleshooting with 24/7 online support.

Industry News

March 2026

EU Proposes "Made in EU" Requirements for BESS & BMS

The European Commission has proposed legislation requiring BESS projects 1MWh to include EU-made battery management systems within one year of enactment.[reference:0]

Read more →
July 2026

Southeast Asia Energy Storage Market Poised for 100GWh Growth

Driven by renewable energy targets in the Philippines, Vietnam, and Thailand, Southeast Asia is expected to add 100GWh of energy storage capacity from 2026–2030.[reference:1]

Read more →
August 2026

CIES 2026: 16th China International Energy Storage Conference

The premier energy storage industry event will take place in Hangzhou, gathering 300+ organizations to discuss BMS technology, policy, and market trends.[reference:2]

Read more →

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000